Monitors 1500 Series Flow Monitor

1500_panel1500_wall-gif

An economical, compact digital meter displays flow rate and flow total on alphanumeric display. Calibration, selection of measurement units and output programming is menu driven using keypad.

Series 1500
Compact Digital Flow Monitor

The Data Industrial Series 1500 Flow Monitor is an economical, full featured, digital flow monitor.

The two line x 8 character alphanumeric display can be configured by the user to display flow rate and flow total separately or simultaneously.

The panel meter has a NEMA 4X rated front panel and conforms to DIN Standard dimensions, 96 mm X 96 mm, for meter sizes and panel cutouts. Versions of the Series 1500 are also available in NEMA 4 wall mount or sensor mount configurations.

Like all Data Industrial flow monitors, the Series 1500 may be field calibrated by the user. Data Industrial sensors are calibrated by entering "K" and offset numbers, while other pulse or frequency output sensors may only use a "K" factor. The Series 1500 accepts pulse, sine wave, or an optional 4-20 mA analog input signal.

Series 1500 w / NEMA 4X Wall Mount Enclosure

Programming is menu driven. All data is entered using the LCD/keypad interface. A password gate is included to prevent unauthorized access to system parameters. Programming flexibility is extended to units of measure. Series 1500 software contains eight flow rate and four total flow units of measure. There is also a provision for adding custom units for rate and total.

The Series 1500 provides two pulse outputs to interface with external data collection devices that accept electronic pulses, one is a function of flow rate, the other flow total. The resolution of this TTL compatible signal may be programmed via the user interface.

Two LED's are located on the front panel. One is an indication of power. The other is programmed to represent impeller status, totalizer status, or alarm status.

All calibration information, units of measure and flow totals are stored in a non-volatile memory that does not require battery back-up for data retention.

Options:

  • Control relays- SPST mechanical relays, 2 available: Fixed as 1 for rate and 1 for totalization functions.
  • Analog output- isolated current sinking 4-20 mA, programmed from the keypad.
  • Analog input- allows the use of other flow devices with analog outputs.

 