Refining, Chemical & Petrochemical

As a worldwide leader in flow metering technologies for over 110 years, Badger Meter offers one of the broadest product portfolios for the chemical and petrochemical processing industry. From differential pressure and Coriolis flow meters to advanced control valves, our solutions help you measure what matters and improve the efficiency and reliability of your operations. Badger Meter has the proven tools and expertise to help you manage your critical resources.

Refining, Chemical & Petrochemical

Benefits of Chemical and Petrochemical Solutions

Solutions for Every Application

We support both the efficient processing of high-value products and the safe operation of production facilities.

Measurable Performance

Our solutions will help you improve the efficiency, reliability and safety of your operations.

Increased Standards Requirements

Badger Meter delivers robust solutions to help chemical firms ensure the safety of their workers and the environment, complying with strict standards set by the U.S. Environmental Protection Agency (EPA), American Society for Testing and Materials (ASTM), American Society of Mechanical Engineers (ASME), Canadian Registration Numbers (CRN), International Society of Automation (ISA), and other regulatory bodies.

Related Products

Filter products
Showing units in {{data.selectedUnit == "us" ? data.usLabel : data.metricLabel}} Switch to {{data.selectedUnit == "us" ? data.metricLabel : data.usLabel}}
Filtered by:
Remove all filters
Product category
Product type / technology
{{isTruncated ? openText : closeText}}
Product line
{{isTruncated ? openText : closeText}}
Size
to
Measuring medium
Flow range
to
Temperature range
to
Pressure range
to

Displaying {{pageRange}} of {{data.totalResults}}

Electronic preset meter LM OG-PND DC for non-custody transfers
Size
1/2" BSP
1/2" BSP
Flow Range
1...30 lpm
0.27...7.92 gpm
Pressure Range
0.35...65 bar
5.08...942.74 psi
Temperature Range
-5...50°C
23...122°F
FC30 Flow Computer
Operating Temperature Range
0…50 °C
32...122 °F
Power Requirements
110V AC: 85...127V rms at 50/60 Hz
220V AC: 170...276V rms at 50/60 Hz
10...14V DC, 14...28V DC: 300 mA Max
110V AC: 85...127V rms at 50/60 Hz
220V AC: 170...276V rms at 50/60 Hz
10...14V DC, 14...28V DC: 300 mA Max
Linearization
40-point linearization table
40-point linearization table
Internal Equations
Strouhal-Roshko, API 2540 and AGA-7
Strouhal-Roshko, API 2540 and AGA-7
Model VILPL Venturi Low Pressure Loss, Insert Flow Meter
Size
13...1524 mm
1/2...60 in.
Temperature Range
Max. 815°C
Max. 1500°F
Flow Range
0.95...832,791 lpm
0.25...220,000 gpm
Pressure Range
Max. 620 bar
Max. 9000 PSI
Accuracy
(uncalibrated) ±3% (calibrated) max. ±0.5%
(uncalibrated) ±3% (calibrated) max. ±0.5%
Model 9000 Globe Style Control Valve
Size
25...50 mm
1...2 in.
Temperature Range
38…538 °C
100…1000 °F
Flow Range
0.017…21 kv
0.02…25 cv
Pressure Range
Up to 49 bar
Up to 720 PSI
Nutating disc meter RCDL AdBlue®
Size
M25 and M40

with R3/4" and R1"

M25 and M40

with R 0.75" and R1"

Pressure range
16 bar
232 psi
Flow range
M25 M40
1 - 100 l/min 2 - 160 l/min
M25 M40
0,26 - 26,42 gpm 0,53 - 42,26 gpm
Temperature range
up to 50°C
up to 122°F
Nutating disc meter RCDL nickel coated, for clean and moderately dirty fluids
Size
M25 - M170

15 DN - 50 DN

R3/4" - R1-1/4"

1-1/2" - 2" NPT

M25 - M170

R3/4" - R1-1/4"

1-1/2" - 2" NPT

Temperature Range (PPO)
up to 50°C
up to 122°F
Temperature range (Vectra)
0 - 120°C
0 - 248°F
Flow range (PPO)
1 - 643 l/min
0,26 - 169,86 gal/min
Nutating disc meter RCDL, plastic housing, for clean and moderately dirty fluids
Type
M25 and M40
M25 and M40
Size
DN15...DN25

 

DN15...DN25

 

Temperature range
0…120 °C
0…248°F
Flow range
1…160 lpm
0.26…42 gpm
Nutating disc meter RCDL, stainless steel housing, for clean and moderately dirty fluids
Type
M25 and M40

 

M25 and M40

 

Size
6096 mm and 7620 mm
DN20 and DN25
Flow range (PPO)
1…160 lpm
0.26...42 gpm
Flow range (Vectra)
3…100 lpm
0.79…26 gpm
Pulse transmitter series LM OG TI 100 Alu, for industrial applications
Flow Range
0.5…35 lpm
0.14…9.24 gpm
Temperature range
-20…80°C
-4…176°F
Pressure range
0.35…100 bar
5.08…1450.38 psi
Accuracy
± 0.5%
± 0.5%

We’re sorry, your request didn’t return any products.

Please try again or contact us

Displaying {{pageRange}} of {{data.totalResults}}

Prev Page
1 2 3 ... 15 16
Next Page

Find a distributor
Our extensive global network of distributors is ready to serve you in your local language at your time zone.

For Europe and Africa

For Asia Pacific

For the United Arab Emirates