{{title}}
Request a quote {{contactOpenText}}
Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Find a distributor
Our extensive global network of distributors is ready to serve you in your local language at your time zone.

For Europe and Africa

For Asia Pacific

For the United Arab Emirates

Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Find a distributor
Our extensive global network of distributors is ready to serve you in your local language at your time zone.

For Europe and Africa

For Asia Pacific

For the United Arab Emirates

VN2000 Compact Direct Insertion Meter

The VN2000 Compact Direct Insertion Vortex Flow Meter measures the volumetric or mass flow rate of steam, gases or liquids over a large flow range. The meter is a heavy duty design engineered to stand up to the most abusive environments inside and outside the pipe.

Showing units in {{labelText}}
  • Size
    50...600 mm
    2...24 in.
  • Temperature Range
    –120…204°C
    -250...400 °F
  • Flow Range
    49…8,570 lpm
    13…38,500 gpm
  • Pressure Range
    Up to 68.9 bar
    Up to 1000 PSI
  • Accuracy
    +/- 1 %
    +/- 1 %
Request a quote

Reliable, Easy to Install Compact Insertion Meter.

Ideal for accurately measuring liquids, compressed air and saturated steam. No moving parts and virtually maintenance-free once installed.

  • Reduced Installation Errors. Mounting Kit included to simplify the installation and ensure proper installation depth and orientation for a specified pipe size
  • Reliable measurement for steam and a variety of fluids. Heavy duty design engineered to stand up to the most abusive environments inside and outside the pipe
  • Reduced Maintenance Costs and Spare Parts. No internal o-rings or seals of any kind and absolutely no leak paths into the sensors or electronics. Our sensors do not touch the process fluid, which gives them an almost unlimited life span.


Product Specifications

View & Configure CAD/BIM Drawings Download CSI Specifications
Showing units in {{labelText}}
  • Volumetric Flow
    ±1.0% of reading (for Liquids, Gas & Steam)
    ±1.0% of reading (for Liquids, Gas & Steam)
  • Volumetric Flow Repeatability
    ±0.25% of reading (for Liquids, Gas & Steam)
    ±0.25% of reading (for Liquids, Gas & Steam)
  • Mass or Heat Flow
    ±1.0% of reading (for Liquids, Gas & Steam)
    ±1.0% of reading (for Liquids, Gas & Steam)
  • Mass or Heat Flow Repeatability
    ±0.25% of reading (for Liquids, Gas & Steam)
    ±0.25% of reading (for Liquids, Gas & Steam)
  • Velocity – Liquid
    0.402…9 m/s
    1.32…32 ft/s
  • Velocity – Gas
    cube root (140/ρ) ft/s… 300 ft/sec (91 m/sec)
    cube root (140/ρ) ft/s… 300 ft/sec (91 m/sec)
  • Reynolds Range
    10,000…7,000,000 depending on fluid density
    10,000…7,000,000 depending on fluid density
  • Straight Run Pipe
    Upstream 10 diameters; downstream 5 diameters with one 90° elbow before the meter
    Upstream 10 diameters; downstream 5 diameters with one 90° elbow before the meter
  • Pipe Sizes
    50…1200 mm
    2…24 in.
  • Fluid temperature
    –120…204°C
    –250…400° F
  • Maximum Pressure
    Up to 68.9 bar
    Up to 1000 psi
  • Wetted Materials
    Stainless steel 304L
    Stainless steel 304L
  • Connections
    1-1/2 in. carbon steel mounting assembly Sealing assembly: Two ethylene propylene O-rings
    1-1/2 in. carbon steel mounting assembly Sealing assembly: Two ethylene propylene O-rings
View all Specifications

Market Applications

  • Building Design, HVAC & Plumbing

    Flow instrumentation solutions are a crucial aspect of building design, construction and operation for apartments, hospitals, schools, factories and other facilities. From HVAC and grounds management to plumbing and water services, our flow meters are specifically designed to provide solutions that are accurate and reliable, even under the most challenging conditions.

    View Solutions
  • Utility Water Treatment & Distribution

    Water and wastewater treatment facilities have the critical job of producing a safe supply of high-quality drinking water. Their operational processes are complex and involve a wide range of flow measurement tasks. These applications demand the highest flow meter accuracy and reliability, as well as long-term stability and a low cost-of-ownership. Badger Meter water treatment solutions meet the challenge and are part of our end-to-end portfolio of products for the water utility industry.

    View Solutions

Product Documentation

Share all documents via email

Select up to 5 to share via email

You may only share up to (5) via email. Please remove some.

Software & Firmware

Filter Downloads
Filtered by:
Remove all filters
Product Line
{{isTruncated ? openText : closeText}}
Product / Model

Before filtering by product or model, please select a brand from the filter above.

{{isTruncated ? openText : closeText}}
Download Type
Language
{{isTruncated ? openText : closeText}}

Displaying {{pageRange}} of {{data.totalResults}}

Software | Version 2.1.2.0 | Updated March 28, 2023 | 41.48 MB Vortex VN2000 Sizing Software Vortex See Release Notes Minor bug fixes
Software | Version 2.1.2.0 | Updated March 28, 2023 | 41.48 MB Vortex VN2000 Sizing Software Vortex See Release Notes

We’re sorry, your request didn’t return any software or firmware.

Please try again or contact us

Displaying {{pageRange}} of {{data.totalResults}}

Prev Page
Next Page
We're here to help
Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Find a distributor
Our extensive global network of distributors is ready to serve you in your local language at your time zone.

For Europe and Africa

For Asia Pacific

For the United Arab Emirates