{{title}}
Request a quote {{contactOpenText}}
Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

For sales & general inquiries
Municipal Water solutions: (800) 616–3837
Commercial & Industrial solutions: (877) 243–1010
Wyco Concrete solutions: (800) 233-9926
Telog: 888‑835‑6437 (Press #1)

For product support
Municipal Water solutions: (800) 616–3837
Commercial & Industrial solutions: (877) 243–1010
Wyco Concrete solutions: (877) 243–1010
Telog: 888‑835‑6437 (Press #1)

Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

For sales & general inquiries
Municipal Water solutions: (800) 616–3837
Commercial & Industrial solutions: (877) 243–1010
Wyco Concrete solutions: (800) 233-9926
Telog: 888‑835‑6437 (Press #1)

For product support
Municipal Water solutions: (800) 616–3837
Commercial & Industrial solutions: (877) 243–1010
Wyco Concrete solutions: (877) 243–1010
Telog: 888‑835‑6437 (Press #1)

340 BN/MB BTU Energy Transmitter

The 340 BN/MB BTU Energy Transmitter is an economical, compact device for sub-metering applications using the BACnet or Modbus® communications protocol.

Showing units in {{labelText}}
  • Temperature Range
    0...70 °C
    32...158 °F
Request a quote

An economical, compact device for sub-metering applications.

Calculates thermal energy using the signal from a flow sensor installed in a hydronic heating or chilled water system, and the signals from two 10 kΩ temperature thermistors, 100 Ω RTDs or 1000 Ω RTDs installed in the system’s inlet and outlet points.

  • On-board microcontroller and circuitry make precise measurements and produce accurate, drift-free outputs
  • Calibration information for the flow sensor type and pipe size may be preselected or entered by the user in the field
  • Calculates thermal energy using the signal from a flow sensor installed in a hydronic heating or chilled water system
  • Compact cast epoxy body 


Specifications

Download CSI Specifications
Showing units in {{labelText}}
  • Power Supply Options
    Power supply: 12…24V AC | 12…35V DC
    Current draw: 115 mA max. at 12V DC
    Power supply: 12…24V AC | 12…35V DC
    Current draw: 115 mA max. at 12V DC
  • Pulse Type Sensors - Signal Amplitude
    2.5V DC threshold
    2.5V DC threshold
  • Pulse Type Sensors - Signal Limits
    Vin < 12V (DC or AC peak)
    Vin < 12V (DC or AC peak)
  • Pulse Type Sensors - Frequency Range
    4…1000 Hz
    4…1000 Hz
  • Pulse Type Sensors - Pull-up
    15V DC @ 2k Ω source Impedance
    15V DC @ 2k Ω source Impedance
  • Sine Wave Sensors - Signal Amplitude
    30 mV p-p threshold
    30 mV p-p threshold
  • Sine Wave Sensors - Signal Limits
    Vin < 12V (DC or AC peak)
    Vin < 12V (DC or AC peak)
  • Sine Wave Sensors - Frequency
    4…1000 Hz
    4…1000 Hz
  • Power Out Terminal
    15V DC ± 1V DC @ 500 Ω source Impedance
    15V DC ± 1V DC @ 500 Ω source Impedance
  • Temperature Sensor (2 of same type required) Input
    • 10k Ω thermistor, 2 wire, type II, 10k Ω @ 25° C (77° F)
    • 100 Ω platinum RTD, DIN calibration curve, conforms to IEC-751 Standard
    • 1000 Ω platinum RTD, DIN calibration curve, conforms to IEC-751 Standard
    Calibration range of measurement 0…150° C (32…302° F)
    • 10k Ω thermistor, 2 wire, type II, 10k Ω @ 25° C (77° F)
    • 100 Ω platinum RTD, DIN calibration curve, conforms to IEC-751 Standard
    • 1000 Ω platinum RTD, DIN calibration curve, conforms to IEC-751 Standard
    Calibration range of measurement 0…150° C (32…302° F)
  • Communication Port
    RS-485 with termination, pull-up and pull-down jumpers
    RS-485 with termination, pull-up and pull-down jumpers
  • Pulse Output
    • Isolated solid-state switch in any standard or custom total units
    • Adjustable 50 ms to 1.0 second pulse output width in 50 ms increments
      Maximum sinking current: 100 mA @ 36V DC
    • Isolated solid-state switch in any standard or custom total units
    • Adjustable 50 ms to 1.0 second pulse output width in 50 ms increments
      Maximum sinking current: 100 mA @ 36V DC
  • Temperature
    Operating: 0…70 °C
    Storage: – 40…85 °C 
    Operating: 32…158 °F
    Storage: – 40…185 °F
  • Weight
    4.8 oz with connector headers installed
    4.8 oz with connector headers installed
  • Sensor Calibration
    Badger Meter: Use K and offset values provided in sensor manual
    Other Sensors:  Check with respected manufacturer of flow sensor and with factory
    Badger Meter: Use K and offset values provided in sensor manual
    Other Sensors:  Check with respected manufacturer of flow sensor and with factory
  • Units of Measure - Flow Measurement
    Rate: gpm, gph, l/sec, l/min, l/hr, ft3/sec, ft3/min, ft3/hr, m3/sec, m3/min, m3/hr
    Total: Gallons, Gallons X 100, Gallons X 1000, Liters, Cubic Feet, Cubic Meters
    Rate: gpm, gph, l/sec, l/min, l/hr, ft3/sec, ft3/min, ft3/hr, m3/sec, m3/min, m3/hr
    Total: Gallons, Gallons X 100, Gallons X 1000, Liters, Cubic Feet, Cubic Meters
  • Units of Measure - Energy Measurement
    Rate: kBtu/min, kBtu/hr, kW, MW, hp, tons
    Total: Btu, kBtu, MBtu, kWh, MWh, kJ, MJ
    Rate: kBtu/min, kBtu/hr, kW, MW, hp, tons
    Total: Btu, kBtu, MBtu, kWh, MWh, kJ, MJ
  • Temperature Measurement
    Fahrenheit, Centigrade
    Fahrenheit, Centigrade
  • Programming
    • Requires PC or laptop running Windows 2000, XP, Vista or Windows 7
    • Data Industrial 340BN/MB Programming Kit A-301-20 containing software and Data Industrial Series programming cable is required for programming and setup
    • Requires PC or laptop running Windows 2000, XP, Vista or Windows 7
    • Data Industrial 340BN/MB Programming Kit A-301-20 containing software and Data Industrial Series programming cable is required for programming and setup
View all Specifications

Market Applications

  • Building Design, HVAC & Plumbing

    Flow instrumentation solutions are a crucial aspect of building design, construction and operation for apartments, hospitals, schools, factories and other facilities. From HVAC and grounds management to plumbing and water services, our flow meters are specifically designed to provide solutions that are accurate and reliable, even under the most challenging conditions.

    View Solutions

Product Documentation

Filter Documents
Filtered by:
Remove all filters
Document Type
{{isTruncated ? openText : closeText}}

Select up to 5 to share via email

Email Selected Documents ({{data.emailDocs.length}})

You may only share up to (5) via email. Please remove some.

Displaying {{pageRange}} of {{data.totalResults}}

We’re sorry, your request didn’t return any documents.

{{data.didYouMean[0]}}? Please check your search term.

Please try again or contact us

Select up to 5 to share via email

Email Selected Documents ({{data.emailDocs.length}})

You may only share up to (5) via email. Please remove some.

Displaying {{pageRange}} of {{data.totalResults}}

Prev Page
Next Page
We're here to help
Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

For sales & general inquiries
Municipal Water solutions: (800) 616–3837
Commercial & Industrial solutions: (877) 243–1010
Wyco Concrete solutions: (800) 233-9926
Telog: 888‑835‑6437 (Press #1)

For product support
Municipal Water solutions: (800) 616–3837
Commercial & Industrial solutions: (877) 243–1010
Wyco Concrete solutions: (877) 243–1010
Telog: 888‑835‑6437 (Press #1)