Metallic Tee Type Flow Sensors - Series 250

The Series 250 flow sensor features a six-bladed impeller design with a proprietary non-magnetic sensing mechanism, mounted in a cast bronze housing, with female NPT threads.The unique impeller design is less prone to be fouled by waterborne debris. The forward curved shape coupled with the absence of magnetic drag provides improved operation and repeatability even at lower flow rates. This is especially true where the impeller is exposed to metallic or rust particles found in steel or iron pipes.

Showing units in {{labelText}}
  • Size
    12.7...38.1 mm
    1/2...1-1/2 in.
  • Temperature Range
    Up to 105° C
    Up to 221° F
  • Flow Range
    0.09…9.144 m/sec
    0.03...30 ft/sec
  • Pressure Range
    Up to 27 bar
    Up to 400 PSI
Request a quote

Provides higher, more consistent torque than four-bladed impeller designs.

Used in conjunction with any Badger Meter impeller flow monitor or transmitter, Badger Meter non-magnetic flow sensors provide an accurate reading of the rate of liquid flow as well as total accumulated flow.

  • Impeller, bearing and shaft are easily replaced in field
    without changing calibration
  • Sensor electronics easily removed from tee
  • Two-wire sensor—power and signal transmit on single pair of wires up to the distance of 2000 feet (610 meters)
  • Digital signal easily interfaced with transmitters, monitors, or PLC’s


Product Specifications

View & Configure CAD/BIM Drawings Download CSI Specifications
Showing units in {{labelText}}
  • Temperature Ratings
    Standard Version 105° C continuous service
    Irrigation Version 66° C continuous service
    Standard Version 221° F continuous service
    Irrigation Version 150° F continuous service
  • Maximum Pressure at 100 °F
    400 psi
    400 psi
  • Recommended Design Flow Range
    0.15…9 m/sec
    0.3…15 ft/sec
  • Accuracy
    ±1.0% of full scale over recommended design flow range
    ±1.0% of full scale over recommended design flow range
  • Repeatability
    ± 0.7% over recommended design flow range
    ± 0.7% over recommended design flow range
  • Linearity
    ± 0.7% over recommended design flow range
    ± 0.7% over recommended design flow range
  • Rangeability
    60:1
    60:1
  • Transducer Excitation
        • Supply voltage = 8V DC min. 35V DC max.
          Quiescent current = 600 uA (typical)
          OFF State (VHigh) = Supply voltage – (600 uA * Supply
          impedance)
          ON State (VLow) = 1.2V DC @ 40 mA (15 Ω + 0.7V DC)
        • Supply voltage = 8V DC min. 35V DC max.
          Quiescent current = 600 uA (typical)
          OFF State (VHigh) = Supply voltage – (600 uA * Supply
          impedance)
          ON State (VLow) = 1.2V DC @ 40 mA (15 Ω + 0.7V DC)
  • Electrical Cable for IR Sensor Electronics
    48 in (122 cm) of UL style 116666 copper solid AWG 18 wire with direct burial insulation. Rated to 221° F (105° C).
    48 in (122 cm) of UL style 116666 copper solid AWG 18 wire with direct burial insulation. Rated to 221° F (105° C).
  • Electrical Cable for Standard Sensor Electronics
    20 ft (610 cm) of 2-conductor AWG 20 with AWG 22 drain wire shielded UL type PTLC wire provided for connection to display or transmitter unit. Rated to 221°
    F (105° C). May be extended to a maximum of 2000 ft (610 m) with similar cable and insulation appropriate for application.
    20 ft (610 cm) of 2-conductor AWG 20 with AWG 22 drain wire shielded UL type PTLC wire provided for connection to display or transmitter unit. Rated to 221°
    F (105° C). May be extended to a maximum of 2000 ft (610 m) with similar cable and insulation appropriate for application.
View all Specifications

Market Applications

  • Building Design, HVAC & Plumbing

    Flow instrumentation solutions are a crucial aspect of building design, construction and operation for apartments, hospitals, schools, factories and other facilities. From HVAC and grounds management to plumbing and water services, our flow meters are specifically designed to provide solutions that are accurate and reliable, even under the most challenging conditions.

    View Solutions
  • Wastewater Treatment

    Wastewater treatment facilities feature complex operational processes involving a wide range of flow measurement, water quality monitoring and toxic gas detection solutions, designed to conserve water, increase regulatory compliance and safeguard water quality, people and the environment. From individual monitors to multiparameter measurement, our versatile solutions deliver continuous and proactive monitoring for early event detection, odor control, pollution prevention, chemical management and toxic gas detection.

    View Solutions
  • Industrial Process

    The measurement and monitoring of flow, water quality and toxic and combustible gas plays a vital role in industrial processes for consistent delivery of quality control, personnel safety, environmental protection, process monitoring and optimization. Our comprehensive range of robust, real-time and reliable instrumentation provides dependable solutions that are easy to install, simple to maintain, creates safe areas of work and deliver increased regulation compliance.

    View Solutions

Product Documentation

Filter Documents
Filtered by:
Remove all filters
Document Type
{{isTruncated ? openText : closeText}}

Select up to 5 to share via email

Email Selected Documents ({{data.emailDocs.length}})

You may only share up to (5) via email. Please remove some.

Displaying {{pageRange}} of {{data.totalResults}}

We’re sorry, your request didn’t return any documents.

{{data.didYouMean[0]}}? Please check your search term.

Please try again or contact us

Select up to 5 to share via email

Email Selected Documents ({{data.emailDocs.length}})

You may only share up to (5) via email. Please remove some.

Displaying {{pageRange}} of {{data.totalResults}}

Prev Page
Next Page
We're here to help
Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

(800) 616–3837