Measurement & Control Measurement & Control
Connectivity & Communication Connectivity & Communication
Insights & Action Insights & Action
Collaboration & Support Collaboration & Support
{{title}}
Request a quote {{contactOpenText}}
Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

(800) 616–3837

We're here to help
Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

(800) 616–3837

pH Measurement & Monitoring

pH is one of the most important water quality parameters, providing a measure of how acidic or alkaline water is. Even small changes in pH can affect chemical treatment efficiency, corrosion rates, scaling potential, biological processes and overall water quality, making it a critical parameter for drinking water, wastewater and industrial applications. Continuous pH monitoring helps operators identify process changes in real-time, although factors such as temperature, dissolved gases, chemical dosing and sensor maintenance can influence measurement accuracy.

pH

Understanding pH in Water

pH is a logarithmic measure of hydrogen ion activity in a solution and indicates whether water is acidic, neutral or alkaline. The pH scale typically ranges from 0 to 14, with a pH of 7 considered neutral, values below 7 acidic and values above 7 alkaline.

In water systems, pH plays a fundamental role in chemical equilibrium, treatment efficiency and water stability. It influences the solubility of metals, the effectiveness of disinfectants, coagulation performance, biological treatment processes and corrosion or scaling tendencies.

Natural water pH is affected by dissolved carbon dioxide, bicarbonate alkalinity, mineral content and biological activity, while treatment processes such as chemical dosing, disinfection and remineralization can intentionally alter pH levels. Monitoring is used throughout municipal drinking water treatment, wastewater treatment, industrial process water, power generation, food and beverage production, agriculture, pulp and paper manufacturing and environmental monitoring programs.

Importance of pH Monitoring

Monitoring pH provides insight into water chemistry and process performance. In drinking water treatment, pH influences coagulation, disinfection and corrosion control. During chloramination, pH affects the equilibrium between ammonia and ammonium as well as the distribution of free chlorine species, influencing monochloramine formation and disinfection performance. Utilities may adjust pH based on source water chemistry and specific treatment objectives.

In wastewater treatment, pH directly affects microbial activity, biological treatment and nutrient removal. It is also commonly monitored in treated effluent to verify that discharge conditions meet applicable permit requirements, which can vary by facility and regulatory authority.

Fluctuations may indicate chemical overdosing, contamination events, biological instability or changing source water conditions. Low pH can increase corrosion and metal leaching, while elevated pH can contribute to scale formation and affect treatment performance. Sudden changes may indicate process disturbances that require investigation.

Benefits of pH monitoring include:

  • Optimize disinfection chemical dosing by maintaining the pH window where chlorine and chloramine treatment is most effective, since disinfectant speciation and efficacy are highly pH-dependent
  • Help manage corrosion and scaling in distribution infrastructure, protecting pipe integrity and water quality at the point of use
  • Maintain biological treatment performance in activated sludge and nitrification systems, where microbial activity is highly pH-sensitive
  • Support regulatory compliance and effluent quality verification across drinking water, wastewater, and industrial discharge applications

Typical pH Ranges by Application

Target pH ranges vary based on water chemistry, treatment objectives, process conditions and regulatory requirements. The following ranges provide general reference points for common water, wastewater and industrial applications.

Application Typical pH Range Why pH Matters
Drinking Water 6.5–8.5 Influences treatment performance, corrosion control and water stability.
Wastewater Effluent 6.0–9.0* Helps maintain effluent quality and meet applicable discharge requirements.
Biological Wastewater Treatment 6.5–8.5* Maintains conditions for microbial activity and biological processes such as nitrification.
Swimming Pools & Recreational Water 7.2–7.8 Balances disinfectant effectiveness, swimmer comfort and corrosion and scale control.
Cooling Water Systems 7.0–9.0* Helps manage corrosion, scale formation and treatment chemical performance.
Industrial Process Water Process-specific Varies by process chemistry, equipment requirements and operational objectives.

*Typical reference ranges only. Target pH may vary based on application, water chemistry, treatment objectives, system design and applicable regulatory requirements.

Because optimal pH varies by application, monitoring trends and changes can be as important as maintaining a specific target range. Continuous measurement helps operators identify deviations that may affect treatment performance, biological activity, corrosion control or regulatory compliance.

How pH is Measured

Measurement methods range from laboratory analysis and field testing to continuous online monitoring, depending on the application and monitoring objective. Laboratory testing is commonly used for regulatory reporting, compliance verification and detailed water quality assessments. Field testing provides immediate measurements during site inspections, troubleshooting or routine operational checks. Continuous monitoring is typically used when operators need ongoing visibility into water quality conditions and real-time process performance.

A key distinction is the difference between periodic testing and continuous monitoring. Periodic testing, whether performed in a laboratory or in the field, provides a snapshot of water conditions at a specific point in time. Continuous monitoring provides an ongoing stream of data, allowing operators to detect changes as they occur and respond more quickly to process variations.

Accurate and repeatable measurements require proper calibration, temperature compensation and representative sampling. Temperature is an important measurement consideration because it affects both electrode response and the actual pH of the sample. Automatic temperature compensation (ATC) corrects for changes in the electrode's response, or slope, but it does not correct for changes in sample pH caused by temperature-dependent chemical equilibria. Readings should therefore be evaluated with the temperature at which they were measured.

Regular verification and careful measurement practices help maintain reliable data for operational and treatment decisions.

How pH Electrodes Work

A pH electrode does not react with the water it measures; it generates a voltage. The sensing element is a thin, pH-sensitive glass membrane that forms a hydrated gel layer when wetted. Within this layer, hydrogen ions from the sample exchange with alkali metal ions bound in the glass, creating a small electrical potential at the membrane surface that varies with the hydrogen ion activity of the sample.

Because the inside of the membrane is filled with a buffer of fixed pH, the potential difference across the glass changes predictably with sample pH. This follows the Nernst relationship of approximately 59 mV per pH unit at 25 °C.

A single potential cannot be measured in isolation, so every pH electrode also requires a reference electrode. This is typically a silver/silver chloride element in a potassium chloride electrolyte that maintains a stable potential regardless of the sample's chemistry. The reference connects to the sample through a diaphragm, or liquid junction, that permits ionic contact while restricting mixing.

In a combination electrode, the measuring and reference elements are built into a single body, with the reference electrolyte surrounding the central glass stem.

Factors That Influence pH

Several chemical, physical and operational factors can affect pH levels in water systems, often interacting in ways that influence water stability and treatment performance.

Dissolved carbon dioxide is a significant influence because it forms carbonic acid in water and affects the balance between bicarbonate, carbonate and hydrogen ions. Changes in carbon dioxide levels can cause pH to shift as water interacts with the atmosphere or undergoes biological and treatment processes.

Alkalinity affects how strongly water resists changes in pH, particularly during chemical dosing, while mineral content and dissolved salts influence overall water chemistry. The carbonate-bicarbonate equilibrium created by these interactions plays an important role in water stability, corrosion control and treatment performance.

Chemical dosing, including caustic soda, lime, sulfuric acid and carbon dioxide, is commonly used to intentionally adjust pH during treatment. The appropriate target depends on the application, water chemistry and treatment objective.

Biological processes such as nitrification, photosynthesis and respiration can influence pH by changing water chemistry. In surface water, photosynthesis consumes dissolved carbon dioxide and releases oxygen, often causing pH and dissolved oxygen to rise during the day. Respiration can reverse this pattern overnight, contributing to daily fluctuations in both parameters.

Temperature affects chemical equilibria in water and can change the actual pH of a sample. It also influences electrode response, making temperature an important consideration when interpreting and comparing measurements.

Understanding how these factors interact helps operators interpret pH trends and identify whether changes are related to source water conditions, treatment processes or other operational influences.

pH Monitoring Challenges

Accurate monitoring can be affected by sensor condition, water chemistry, electrical interference and sampling conditions. Fouling, coating, calibration drift and reference electrode degradation can contribute to unstable readings or measurement drift. Very low-conductivity water, including ultrapure water, can produce unstable or drifting readings due to limited ionic conductivity and changes in liquid junction potential. At high pH, some glass electrodes may also respond to sodium ions, causing measurements to read below the actual pH. These conditions may require specialized electrodes and application-specific measurement practices.

Many electrode-related issues originate in the reference system. Particulates, biofilm, grease, scale and chemical precipitates can obstruct the diaphragm, restricting electrolyte flow and causing sluggish response, noisy readings or measurement drift. A partially blocked electrode may still calibrate correctly in clean buffer solutions, allowing the issue to go undetected under actual process conditions.

Reference poisoning can occur if electrolyte flow stops or the pressure gradient reverses, allowing sample constituents such as sulfides, cyanide and certain heavy metals to enter the reference system and contaminate or damage the reference element. Because changes in reference potential directly affect the measured value, the resulting pH reading may appear plausible even when it is inaccurate.

Electrical interference from pumps, variable-frequency drives, mixers or other equipment can cause readings to fluctuate independently of actual changes in the water. Because pH measurement relies on a small, high-impedance electrical signal, stray currents and electrical noise can distort readings. These fluctuations may coincide with equipment operation and resemble electrode deterioration, making proper grounding, shielding and measurement configuration important troubleshooting considerations.

Sample collection and handling can introduce additional uncertainty. Changes in temperature, aeration or dissolved carbon dioxide between collection and analysis can alter the sample, making representative sampling and proper measurement practices important when evaluating results.

Solutions for pH Monitoring

Several technologies are available for pH measurement, ranging from laboratory benchtop analyzers and portable testing instruments to online process analyzers and networked monitoring systems. Laboratory measurements are often used for quality assurance, validation and regulatory reporting, while online analyzers support continuous process control and operational optimization.

Many of these technologies rely on electrochemical sensing using glass electrodes, combination electrodes or differential pH sensors. The appropriate monitoring approach depends on required accuracy, process conditions, maintenance requirements and the frequency of measurement needed to support operational objectives.

Conventional vs. Differential pH Measurement

Both conventional and differential pH measurement use the same electrochemical principles, relying on a pH-sensitive glass electrode and reference system to determine pH. The primary differences lie in how electrode signals are measured and how each configuration responds to electrical interference and reference electrode issues.

Conventional 2-Electrode pH Measurement

In a conventional configuration, the pH-sensitive glass electrode is measured directly against a reference electrode. The potential difference between these two half-cells (U = E₁ – E₂) is converted into a pH value, with a theoretical response of approximately –59.2 mV per pH unit at 25 °C (0 mV at pH 7).

Because the reference electrode also serves as the measuring common, coating, junction blockage or stray electrical currents can shift the measured potential and appear as changes in pH. Without a separate reference diagnostic signal, these disturbances may be difficult to distinguish from actual process variations.

The diagram below illustrates the two-electrode configuration and how the potential difference between the glass and reference electrodes is measured.*

Conventional two-electrode pH measurement diagram

Differential 3-Electrode pH Measurement

In a differential configuration, the glass electrode and reference electrode are each measured independently through separate amplifiers against a common third element—a metal solution ground, typically titanium or stainless steel, in direct contact with the process water. The two measurements are then subtracted to determine pH.

The solution ground provides a dedicated return path for stray electrical currents, helping reduce interference. The separate reference signal (V₂) can also be monitored to help identify reference electrode issues, such as coating, junction blockage or depleted electrolyte, depending on the sensor and transmitter design.

The diagram below illustrates the three-electrode configuration, showing how the glass and reference electrode signals are measured separately against the solution ground before being combined to determine pH.*

Differential three-electrode pH measurement diagram

* Schematics are not to scale. Temperature sensors, cable shielding and preamplifiers are omitted. Both electrochemical half-cells are often incorporated into a single combination electrode body.

Continuous pH Monitoring Systems

Continuous monitoring provides ongoing pH measurements that can support process control and operational optimization. These systems can also be integrated into broader water quality monitoring programs that measure parameters such as conductivity, dissolved oxygen, oxygen reduction potential (ORP/redox), turbidity, chlorine and temperature.

Process conditions and maintenance requirements are important considerations when selecting a monitoring solution. In applications prone to fouling or coating, automated cleaning mechanisms can help reduce buildup and support more consistent measurement performance.

Badger Meter offers pH monitoring solutions ranging from portable and physical sensors to multiparameter monitoring platforms, water quality monitoring stations and data management technologies for drinking water, wastewater and industrial applications.

Related Parameters to pH

pH is closely connected to other water quality parameters, including dissolved oxygen, chlorine, ammonium and alkalinity. Changes in pH can influence biological activity, disinfection effectiveness and chemical stability, while alkalinity affects how strongly water resists pH fluctuations. Monitoring pH alongside oxygen reduction potential (ORP/redox), conductivity, temperature and other parameters provides a more complete understanding of water chemistry and treatment performance.

pH Measurement Instrumentation

Sensors • Analyzers • Testing Equipment • Monitoring Stations

Filter Products
Showing units in {{data.selectedUnit == "us" ? data.usLabel : data.metricLabel}} Switch to {{data.selectedUnit == "us" ? data.metricLabel : data.usLabel}}
Filtered by:
Remove all filters
Water Quality Parameters
{{isTruncated ? openText : closeText}}
Market
{{isTruncated ? openText : closeText}}
Product Type / Technology
{{isTruncated ? openText : closeText}}

Displaying {{pageRange}} of {{data.totalResults}}

MetriNet® Mini Water Quality Monitoring Station
Parameters
Chlorine Dioxide, Combined Chlorine, Conductivity (2E), Dissolved Oxygen (DO), Dissolved Ozone, Fluoride, Free Chlorine (FCI), Hydrogen Peroxide, Nitrite, Oxygen Reduction Potential (ORP), Peracetic Acid (PAA), pH, Pressure, Total Chlorine (TCI), Turbidity

Configurable for any 2 or 3 parameters

Chlorine Dioxide, Combined Chlorine, Conductivity (2E), Dissolved Oxygen (DO), Dissolved Ozone, Fluoride, Free Chlorine (FCI), Hydrogen Peroxide, Nitrite, Oxygen Reduction Potential (ORP), Peracetic Acid (PAA), pH, Pressure, Total Chlorine (TCI), Turbidity

Configurable for any 2 or 3 parameters

MetriNet® Multiparameter Water Quality Monitor
Parameters

Chlorine Dioxide, Combined Chlorine, Conductivity (2E/4E), Dissolved Oxygen (DO), Dissolved Ozone, Fluoride, Free Chlorine (FCI), Hydrogen Peroxide, Nitrite, Oxygen Reduction Potential (ORP), Peracetic Acid (PAA), pH, Pressure, Total Chlorine (TCI), Turbidity

Chlorine Dioxide, Combined Chlorine, Conductivity (2E/4E), Dissolved Oxygen (DO), Dissolved Ozone, Fluoride, Free Chlorine (FCI), Hydrogen Peroxide, Nitrite, Oxygen Reduction Potential (ORP), Peracetic Acid (PAA), pH, Pressure, Total Chlorine (TCI), Turbidity

micro-station Monitoring Station for Wastewater
Parameters
Chlorine Dioxide, Color, Conductivity, Dissolved Oxygen (DO), DOC, FCl/TCL, Fingerprint, H2S2, Hydrogen Peroxide, HS, Potassium, NH4-N, NO2-N/NO2, NO3-N/NO3, Oxygen Reduction Potential (ORP), pH, Pressure, PSU, Salinity, Temperature, TOC, TSS, Turbidity, UV254
Chlorine Dioxide, Color, Conductivity, Dissolved Oxygen (DO), DOC, FCl/TCL, Fingerprint, H2S2, Hydrogen Peroxide, HS, Potassium, NH4-N, NO2-N/NO2, NO3-N/NO3, Oxygen Reduction Potential (ORP), pH, Pressure, PSU, Salinity, Temperature, TOC, TSS, Turbidity, UV254
nano-station Monitoring Station
Parameters
Chlorine Dioxide, Color, Conductivity, DOC, Free Chlorine (FCI), Hydrogen Peroxide, Oxygen Reduction Potential (ORP), Peracetic Acid (PAA), pH, TCL, Temperature, TOC, Turbidity, UV, UV254
Chlorine Dioxide, Color, Conductivity, DOC, Free Chlorine (FCI), Hydrogen Peroxide, Oxygen Reduction Potential (ORP), Peracetic Acid (PAA), pH, TCL, Temperature, TOC, Turbidity, UV, UV254
pipe-scan Monitoring System
Parameters
Chlorine, Color, Conductivity, Dissolved Organic Carbon (DOC), Oxygen Reduction Potential (ORP), pH, Pressure, Temperature, Total Organic Carbon (TOC), Turbidity, UV254
Chlorine, Color, Conductivity, Dissolved Organic Carbon (DOC), Oxygen Reduction Potential (ORP), pH, Pressure, Temperature, Total Organic Carbon (TOC), Turbidity, UV254
ammo-lyser Eco Ammonium Physical Sensor
Parameters
Ammonium, NO3-N/NO3, pH, Temperature
Ammonium, NO3-N/NO3, pH, Temperature
M-Node Smart Sensors
Parameters

Chlorine Dioxide, Combined Chlorine, Conductivity (2E/4E), Dissolved Oxygen (DO), Dissolved Ozone, Fluoride, Free Chlorine (FCI), Hydrogen Peroxide, Nitrite, Oxygen Reduction Potential (ORP), Peracetic Acid (PAA), pH, Pressure, Total Chlorine (TCI), Turbidity

Chlorine Dioxide, Combined Chlorine, Conductivity (2E/4E), Dissolved Oxygen (DO), Dissolved Ozone, Fluoride, Free Chlorine (FCI), Hydrogen Peroxide, Nitrite, Oxygen Reduction Potential (ORP), Peracetic Acid (PAA), pH, Pressure, Total Chlorine (TCI), Turbidity

SiteBox Portable Water Quality Monitor
Parameters
Chlorine, Chlorine Dioxide, Conductivity, Dissolved Oxygen (DO), Dissolved Ozone, Dissolved Sulfide, Fluoride, Nitrite, Oxygen Reduction Potential (ORP), Peracetic Acid (PAA), pH, Pressure, Turbidity, UV254
Chlorine, Chlorine Dioxide, Conductivity, Dissolved Oxygen (DO), Dissolved Ozone, Dissolved Sulfide, Fluoride, Nitrite, Oxygen Reduction Potential (ORP), Peracetic Acid (PAA), pH, Pressure, Turbidity, UV254
pH-lyser pH and Temperature Physical Sensor
Parameters
pH, Temperature
pH, Temperature

We're sorry, your request didn't return any products.

Please try again or contact us

Displaying {{pageRange}} of {{data.totalResults}}

Prev Page
1 2 3 ... 15 16
Next Page
We're here to help
Contact a Customer Care Representative

We’ll get back to you within 24 hours or the following business day.

Prefer to call?
Customer Care representatives are available by phone Monday–Friday, from 9am–5pm CST.

(800) 616–3837

All Chats Close
Ask a Question
Previous Chats
Your previous chats will be saved here.
    Start a new chat: